跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

SolidFire 节点上出现 " 绑定 1G 上的已设置网络配置不匹配 " 警告

Views:
7
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

适用场景

  • NetApp SolidFire
  • NetApp HCI 存储节点

问题描述

  • networkConfig从 Active IQ 检测到以下警告。

示例:

Detected network configuration mismatch on Bond1G:
{ - "#default" : false,
+ "#default" : true,
"address" : "xx.xx.xx.xx",
"auto" : true,
"bond-downdelay" : "0",
@@ -9,10 +9,18 @@
"bond-primary_reselect" : "Failure",
"bond-slaves" : "eth2 eth3",
"bond-updelay" : "200",
+ "dns-nameservers" : "xx.xx.xx.xx",
"family" : "inet",
+ "gateway" : "xx.xx.xx.xx",
"method" : "static",
"mtu" : "1500",
"netmask" : "xx.xx.xx.xx",
"network" : "xx.xx.xx.xx",
- "status" : "UpAndRunning"
+ "status" : "UpAndRunning",
+ "symmetricRouteRules" : [ + "ip route add xx.xx.xx.xx/23 dev Bond1G src xx.xx.xx.xx table Bond1G",
+ "ip route add default via xx.xx.xx.xx",
+ "ip route add default via xx.xx.xx.xx dev Bond1G src xx.xx.xx.xx table Bond1G",
+ "ip rule add from xx.xx.xx.xx table Bond1G" + ] }
 
  • 此时将创建集群,并在检测到上述警告之前移除节点的所有 eth3 缆线。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device