跳转到主内容

FRU PSUx 的清单信息不可读

适用场景

  • AFF A220
  • FAS 2554
  • FAS 2650
  • ONTAP 9

问题描述

  • EMS错误消息示例:
Wed May 19 09:56:06 +0000 [node1: env_mgr: monitor.fru.info.unreadable:error]: The inventory information of FRU PSU1 is not readable.
Wed May 19 09:56:06 +0000 [node1: env_mgr: monitor.fru.info.unreadable:error]: The inventory information of FRU PSU2 is not readable.
Wed May 19 10:00:00 +0000 [node1: statd: monitor.fan.failed:alert]: Multiple fans has failed.
Wed May 19 10:44:46 +0000 [node1: env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 4 Temp) is not readable.
Wed May 19 10:44:46 +0000 [node1: env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 3 Temp) is not readable.
Wed May 19 10:44:46 +0000 [node1: env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 2 Temp) is not readable.
Wed May 19 10:44:46 +0000 [node1: env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 1 Temp) is not readable.
Wed May 19 10:45:28 +0000 [node1: env_mgr: monitor.fan.warning:notice]: multiple fans have failed. Replace it to avoid overheating
Wed May 19 10:45:57 +0000 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Multiple fans have failed
 
 
Sun Feb 27 16:08:11 +0900 [node1: env_mgr: monitor.fru.info.unreadable:error]: The inventory information of FRU PSU3 is not readable.
...
Sun Feb 27 17:07:11 +0900 [node1: env_mgr: monitor.fru.info.readable:info]: The inventory information of FRU PSU3 is readable.
  • 平台传感器错误示例:
PSU1 Fan 1 and PSU1 Fan 2 init-failed
PSU2 Fan 1 and PSU2 Fan 2 init-failed
  • sysconfig -a 输出示例: 
Shelf 0: DS224-12 Firmware rev. IOM12E A: 0220 B: ---- 
  • ONTAP 操作系统启动错误: 
LOADER-B> boot_ontap
Loading X86_64/freebsd/image1/kernel:0x200000/1091691 0x30b000/10940288 0xf7a000/3783336 0x1315aa8/13717528
...
***************************************************
This platform is not supported in this release.
The system will now halt
***************************************************
BIOS Version: 11.9
...
Loading Device Drivers ...
Waiting for SP
...
IPMI:Read midplane FRU common header:timeout
SP failure. Resetting SP from primary FW. This can take a few minutes
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.