适用场景

  • AFF A300
  • AFF-A220
  • FAS2720

问题描述

发生接管时会同时发出以下警报:

[Node-01: ctrl_hb_port_ic0a: ctrl.rdma.heartBeat:info]: HA interconnect: Missed heartbeat to 192.0.1.5.
[Node-01: gop_eq: ic.linkStatusChange:info]: HA interconnect: Port ic0a link is down.
[Node-01: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-01 by Node-02 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
[Node-01: cf_main: cf.fsm.takeoverCountdown:info]: Failover monitor: takeover scheduled in 10 seconds

 