跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

由于 NVMEM 子系统初始化失败,系统将关闭 或者,在更换 NDVIMM 后收到配置检查崩溃消息

Views:
12
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • AFF A800
  • NVDIMM
  • ONTAP 9

问题描述

更换 NVDIMM 后,系统将在 30 分钟超时过期后崩溃:

/etc/netapp_loadnvram: 1: not found
Loading NVDIMM1 firmware version 2.6.2.c (was 2.5.2.c)
Programming NVDIMM1 FW. This could take over 8 minutes. Please wait...
..................................................................................Tue May  4 15:53:54 2021 [nvdimm.fw.upgrade.succeed:NOTICE]:NVDIMM controller firmware in slot-23 was upgraded to 2.6.2.c.
.........................................................................................................................................................................................................................................................................

.........[nvdimm.nvmem.initfail:FAULT]:NVDIMM startup failed due to FW upgrade timeout. To prevent NVMEM data loss, halt the system.

**********************************************************************
NVMEM subsystem failed initialization or configuration check
To prevent NVMEM data loss, halt the system.
Set bootarg.init.battery_override can ignore this error and continue to boot.
**********************************************************************
PANIC  : System is going to shutdown because NVMEM subsystem failed initialization or configuration check.

Dumper is not yet registered. A coredump will not be available at this time.
System halting...


 

 