跳转到主内容

MCC-IP 中的 SingleAdapterToShelf , NoPathFromSwitchToNSM 和 NoPathToNSMB 警报

适用场景

  • NS224 磁盘架
  • NSM100 模块固件 1.30
  • MetroCluster IP

问题描述

  • 出现适配器错误的 AutoSupport 消息。示例
 
HA Group Notification (Health Monitor process nchm:
SingleAdapterToShelf_Alert[1741294365895598080]) ALERT
 
Controller node_name1 is connected to shelf 1.20 using ports e0c, e0c on the same adapter.
Controller node_name1 is connected to shelf 1.21 using ports e0c, e0c on the same adapter.
Controller node_name2 is connected to shelf 1.20 using ports e5b, e5b on the same adapter.
NoPathFromSwitchToNSM_Alert
 
NoPathToNSMB_Alert
 
Controller node_name1 is connected only to module B of shelf 1.22 through port e0c, e5b.
Controller node_name2 is connected only to module B of shelf 1.21 through port e0c.
Storage shelf 1.20 module A is not connected to storage switches.
Storage shelf 1.20 module B is not connected to storage switches.
...
存储架 1.22 模块 A 未连接到存储交换机。
Storage shelf 1.22 module A is not connected to storage switches.
  • 几秒钟后清除多个路径,磁盘架和模块的消息:
Sun Aug 29 02:19:53 +0200 [node_name1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 1092776019554246656 raised by monitor node-connect
Sun Aug 29 02:49:54 +0200 [node_name1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 1092776019554246656 cleared by monitor node-connect
Sun Aug 29 02:49:54 +0200 [node_name1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMA_Alert , Alerting Resource = 10389613025330503680 raised by monitor node-connect
Sun Aug 29 03:19:55 +0200 [node_name1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMA_Alert , Alerting Resource = 10389613025330503680 cleared by monitor node-connect
Sun Aug 29 03:49:56 +0200 [node_name1: nchmd: hm.alert.raised:alert]: Alert Id = SingleAdapterToShelf_Alert , Alerting Resource = 1741294365895598080 raised by monitor node-connect
Sun Aug 29 04:19:57 +0200 [node_name1: nchmd: hm.alert.cleared:notice]: Alert Id = SingleAdapterToShelf_Alert , Alerting Resource = 1741294365895598080 cleared by monitor node-connect
  • MetroCluster IP 的一端更新了本地磁盘架 NSM100 模块,但另一端未更新。
Tue Aug 31 09:25:59 +0200 [node_name1: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0x.shelf20 has downrev firmware.
Tue Aug 31 09:25:59 +0200 [node_name1: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0x.shelf21 has downrev firmware.
Tue Aug 31 09:25:59 +0200 [node_name1: dsa_disc: sfu.firmwareDownrev.shelf:error]: Shelf 0x.shelf22 has downrev firmware.
  • NS224 磁盘架已在多路径中正确布线

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.