系统中报告了RTC低功率错误

Views:
3
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009年295333</a>
Last Updated:

适用场景

  • AFF 系统
  • ONTAP 9

问题描述

  • 系统指示灯故障LED。
  • 事件日志每小时报告一次RTC低功率错误:
Thu Sep 15 00:20:21 [NOde-02: env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.
Thu Sep 15 01:20:22 [NOde-02: env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.
Thu Sep 15 02:20:22 [NOde-02: env_mgr: monitor.rtcLowPower:error]: Real-time clock battery is dangerously low. Replace it at the next available maintenance window.
  • 的状态P3V Batt sensorSP-LATEST-IPMI AutoSupport 的部分中报告为严重不足:

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
P3V Batt          critlow       0 mV   2100 mV    2200 mV    3400 mV    3500 mV 