跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

ONTAP 9.6 及更高版本:在更换磁盘后,系统会发送每周 spares_low AutoSupport

Views:
27
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9.6 及更高版本
  • ADPV2
  • 具有专用核心转储设备的平台
    • AFFA250 , FAS500f
    • AFF-A400 , FAS8700 , FAS8300
    • AFF A220 , FAS2750 , FAS2720
    • AFF A700 、 FAS9000
    • AFF A800
    • AFF A320
    • AFF A300
    • AFF A700

问题描述

  1. 更换磁盘并正确分配磁盘后, ONTAP 会报告 weekly spares_low AutoSupport
  • 分区磁盘出现故障后出现警报。即使在更换后节点上有完整的可用备用磁盘,也会发生这种情况。
 Fri Jun 18 16:00:00 -0400 [node_name: config_thread: callhome.spares.low:error]: Call home for SPARES_LOW
  1. 检查可用备用磁盘将仅显示根分区( P3 ) 并提供一个全磁盘

示例:

cluster::> node run -node * sysconfig -r
[...]

node-01
Pool0 spare disks

RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------   ------     ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block checksum
spare     0b.00.10P3   0b    0   10  SA:A   0   SSD   N/A 23956/49062912    23964/49079296
spare     0b.00.11P3   0b    0   11  SA:A   0   SSD   N/A 23956/49062912    23964/49079296

[...]

node-02
Pool0 spare disks

RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------   ------     ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block checksum
spare     0b.00.22P3   0b    0   22  SA:B   0   SSD   N/A 23956/49062912    23964/49079296
spare     0b.00.15   0b    0   15  SA:B   0   SSD   N/A 915465/1874872832 915715/1875385008

注意: 如果已更换故障磁盘,则此错误不会影响集群。如果另一个分区磁盘出现故障, ONTAP 将默认对可用备用磁盘进行分区。

 