出现电池充电错误 AutoSupport 警报后节点关闭

Views:
45
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用场景

AFF 系列

问题描述

Sat Dec 19 16:22:32 +0100 [CLUSTERBA-CTRLA: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 24 hours.
Sat Dec 19 16:23:27 +0100 [CLUSTERBA-CTRLA: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
... (repeated hourly)
Sun Dec 20 15:23:38 +0100 [CLUSTERBA-CTRLA: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 60 minutes.
Sun Dec 20 15:24:18 +0100 [CLUSTERBA-CTRLA: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
Sun Dec 20 16:22:30 +0100 [CLUSTERBA-CTRLA: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery charging current failed)

  • [1] NVRAM 电池的平台传感器输出:

Battery Charge Failed?       discrete fault  normal TRUE
Battery Capacity Message     discrete failed  failed
Bat Curr                   current  normal  -40 mA
Bat Charging State          discrete fault   normal WRONG_CHARGE

Jan  7 14:17:14 (none) env_mgr[1035]: Payload EMS: EMS_nvmem_battery_wrongCharge(in 24 hours)
Jan  7 14:17:46 (none) env_mgr[1035]: Payload EMS: EMS_callhome_battery_warning(BATTERY (wrong charge))
Jan  7 15:17:20 (none) env_mgr[1035]: Payload EMS: EMS_nvmem_battery_wrongCharge(in 23 hours)
Jan  7 15:17:47 (none) env_mgr[1035]: Payload EMS: EMS_callhome_battery_warning(BATTERY (wrong charge))
...

  • 服务处理器事件输出: 

Record 992: Thu Jan  7 15:17:20 2021 [IPMI.notice]: b502 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
Record 993: Thu Jan  7 15:17:27 2021 [IPMI.notice]: b602 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"

 

  • 当计数器在 24 之后结束时,节点将关闭 小时

 

 