跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

NS224 磁盘架会暂时断开一条路径上的连接

Views:
1
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用场景

  • NS224 驱动器架
  • 具有 0131 固件的 NSM100 模块

问题描述

  • NVMe 磁盘架模块( NSM )报告通过一条路径暂时无法访问
Jan 18, 2022 22:30:48 +0100HA Group Notification (Health Monitor process nchm: NoPathToNSMB_Alert[XXXXXXXXXXXXX]) ALERT
Jan 18, 2022 22:31:17 +0100HA Group Notification (DISK REDUNDANCY FAILED) ERROR
  • EMS 日志显示连接端口已关闭
Tue Jan 18 22:31:11 +0100 [node-01: kernel: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
Tue Jan 18 22:31:11 +0100 [node-01: intr: netif.linkDown:info]: Ethernet e0d-30: Link down, check cable.
  • 系统将显示单路径状态
Cluster::> system node run -node <node name> -command sysconfig -a
 
System Storage Configuration: Single-Path HA
  • 此路径会在短时间后变为可用,而无需任何用户干预
Tue Jan 18 22:31:55 +0100 [node-01: kernel: netif.linkUp:info]: Ethernet e0d: Link up.
Tue Jan 18 22:31:55 +0100 [node-01: intr: netif.linkUp:info]: Ethernet e0d-30: Link up.
Tue Jan 18 22:56:13 +0100 [node-01: dsa_disc: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
 
System Storage Configuration: Multi-Path HA
  • 在此期间未执行磁盘架固件升级