适用场景

运行 NA51 固件的磁盘型号 X357_TPM4V3T8AME

问题描述

  • 型号 X357_TPM4V3T8AME 在重新利用的系统上出现多个磁盘故障。示例:

::> system node run -node * -command sysconfig -a
...
00.0 : NETAPP   X357_TPM4V3T8AME NA51   0.0GB (0 0B/sect) (Startup failed.)
00.1 : NETAPP   X357_TPM4V3T8AME NA51   0.0GB (0 0B/sect) (Startup failed.)
00.2 :  NETAPP   X357_TPM4V3T8AME NA51   0.0GB (0 0B/sect) (Startup failed.)

  • 失败的初始化消息。示例: 

Nov 24 08:34:43 [node_name-01:disk.init.failure.error:error]: Disk 0a.00.0 failed initialization due to error 5.
Nov 24 08:34:43 [node_name-01:disk.readReservationFailed:error]:  Disk read reservation failed on 0a.00.0 CDB 0x5e:01 - SCSI:hardware error (4 44 d1)
Nov 24 08:34:43 [node_name-01:diskown. errorDuringIO:error]: error 23 (adapter error prevents command from being sent to device) on disk 0a.00.0 (S/N )  while reading reservation state

 