跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

NSF224 磁盘架上的模块固件升级已停止

Views:
17
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用场景

  • NS224 架
  • NSM100 固件升级

问题描述

  • 在 NSM100 模块上升级固件期间,自动升级过程永远不会完成。
  • 尝试手动执行升级时,可能会看到类似于以下消息的消息:

Cluster::*> storage shelf firmware update -shelf 10.1

Error: Shelf firmware update request failed on node "node1".
Reason: Shelf firmware update already in progress.
 
  • 有时,固件更新停止后, EMS 会显示以下错误
[Node-1: dsa_worker4: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x temperature warning for Temperature sensor 12: not installed or failed. Current temperature: 23 C (73 F). This element is on the unknown location.
[Node-1: dsa_worker4: ses.status.electronicsWarn:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on module B.
[Node-1: dsa_worker4: ses.status.ModuleWarn:alert]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x PCI switch warning for PCI Switch 2: communication error. This element is on the rear of the shelf at the bottom, on module B.
[Node-1: dsa_worker4: ses.status.battery.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x battery failure error for Coin Battery 2: not installed or hardware failure. This element is on the rear of the shelf, in bottom module (B).
[Node-1: dsa_worker4: ses.status.etherConn.warn:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x Ethernet connector warning for port e0a: cannot communicate with connector.  This element is on the rear of the shelf at the bottom, on le B.
[Node-1: dsa_worker4: ses.status.etherConn.warn:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x Ethernet connector warning for port e0b: cannot communicate with connector.  This element is on the rear of the shelf at the bottom, on module B.
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 5: not installed or failed. This element is on the DIMM slot 1 in the bottom shelf module (B).
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 6: not installed or failed. This element is on the DIMM slot 2 in the bottom shelf module (B).
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 7: not installed or failed. This element is on the DIMM slot 3 in the bottom shelf module (B).
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 8: not installed or failed. This element is on the DIMM slot 4 in the bottom shelf module (B).

 
  • 已生成 AutoSupport 消息 'DISK REDUNDANCY FAILED'

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device

 

  • 这篇文章对您有帮助吗?