重新启动后、FAS/AFF控制器上的端口上的链路关闭
适用场景
- 10/40千兆以太网控制器XL710 QSF++
问题描述
- ONTAP 重新启动后、X710 10G/40G端口的链路随机关闭
- sysconfig -a输出将端口显示为已关闭
slot 8: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e8e MAC Address: 00:a0:98:e8:71:37 (auto-unknown-fd-down)
QSFP Vendor: AVAGO
QSFP Part Number: 332-00389
QSFP Serial Number: QH0200AZ
e8f MAC Address: 00:a0:98:e8:71:38 (auto-10g_sr-fd-up)
QSFP Vendor: AVAGO
QSFP Part Number: 332-00389
QSFP Serial Number: QH0200AZ
e8g MAC Address: 00:a0:98:e8:71:39 (auto-10g_sr-fd-up)
QSFP Vendor: AVAGO
QSFP Part Number: 332-00389
QSFP Serial Number: QH0200AZ
e8h MAC Address: 00:a0:98:e8:71:3a (auto-10g_sr-fd-up)
QSFP Vendor: AVAGO
QSFP Part Number: 332-00389
QSFP Serial Number: QH0200AZ
- EMS日志中可能会显示以下消息、抱怨SFP不受支持、但此SFP受支持
[Node-01: kernel: netif.sfpNotSupported:error]: The SFP+ or QSFP+ module (AVAGO332-00389) installed in e8f is not supported with this network interface.
[Node-01: kernel: netif.sfpNotSupported:error]: The SFP+ or QSFP+ module (AVAGO332-00389) installed in e8g is not supported with this network interface.