跳转到主内容

LUN联机、但在节点从集群中取消加入后无法访问

Views:
4
Visibility:
Public
Votes:
0
Category:
fas-systems<a>UUID</a><a>陈旧条目</a><a>2008860228</a>
Specialty:
san
Last Updated:

适用场景

  • ONTAP 9
  • ESXi
  • SAN
  • FCP

问题描述

  • 问题描述 是通过删除集群节点或在受影响的ONTAP 版本上进行操作而引入的、不一定会立即显而易见  
  • 由于ssan_获 豁免、节点级别的CPU使用率较高
  • 对受影响的LIF执行路径故障转移时、SAN主机丢失访问权限
    • 可能表现为问题描述的情形:因电源故障、温度过高、更新等原因发生HA接管、并导致主机服务器无法正确访问FC (光纤通道)目标。 

2021-07-29T09:18:37.637Z cpu7:2097711)VMW_SATP_ALUA: satp_alua_issueCommandOnPath:735: Path "vmhba2:C0:T7:L51" (UP) command 0xa3 failed with status Timeout. H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.
2021-07-29T09:18:47.637Z cpu7:2097711)VMW_SATP_ALUA: satp_alua_issueCommandOnPath:735: Path "vmhba1:C0:T7:L51" (UP) command 0xa3 failed with status Timeout. H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.
2021-07-29T09:18:57.637Z cpu7:2097711)VMW_SATP_ALUA: satp_alua_issueCommandOnPath:735: Path "vmhba2:C0:T6:L51" (UP) command 0xa3 failed with status Timeout. H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.

 

  • network interface show 显示已从集群中删除的节点的UUID (而不是节点名称):

::*>network interface show
       Logical   Status    Network       Current     Current Is
Vserver    Interface  Admin/Oper Address/Mask     Node      Port   Home
----------- ---------- ---------- ------------------ ------------- ------- ----
FC_vserver
       LIF_1     up/up   20:0b:00:a0:98:xx:xx:xx Node_1    0c   true
       LIF_2     up/up   20:07:00:a0:98:xx:xx:xx Node_2    0d   true
       LIF_3     up/-   20:0c:00:a0:98:xx:xx:xx 507049c5-fd62-11e5-9977-3bcadcfd9d22 0c true
       LIF_4     up/-   20:08:00:a0:98:xx:xx:xx 507049c5-fd62-11e5-9977-3bcadcfd9d22 0d true

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.