对于 NS224 磁盘架, NSM100 模块中的 Coin 电池出现间歇性警告

适用场景

  • NS224 架
  • 0141 磁盘架固件

问题描述

  • NS224 磁盘架模块 NSM100 报告:
Wed Feb 03 18:50:42 +0100 [node_name: dsa_worker3: ses.status.battery.threshErr:alert]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery failure error for Coin Battery 1: critical status. This element is on the rear of the shelf, in top module (A).
Wed Feb 03 19:16:54 +0100 [node_name: dsa_worker3: ses.status.battery.info:notice]: NS224NSM100 (S/N SHFHU0123456789) shelf 0 on channel 0x battery information for Coin Battery 1: normal status.
 
  • 重新拔插模块后、此情况无法清除
  • 更换电池后、此情况不会清除
  • AutoSupport 中的其他指示:
  1. 如果在触发Autossupport之前更正了故障条件、则无法找到此故障的进一步证据。
  2. 如果在之间触发了AutoSupportbattery failure error for Coin Battery 1: critical statusbattery information for Coin Battery 1: normal status 并且在存储故障和环境输出中注册了问题描述 :
  • 存储故障输出
Coin Cell Battery:
Element Status            Status Bytes  Status Descriptions
   1 [NSM100 A]   : CRITICAL     02,02,0A,46  LCR
   2 [NSM100 B]   : OK         01,00,0B,34
  • Coin电池的环境输出: 
Coin Battery installed element list: 1, 2; with error: 1
Coin Battery information by element:
   [1] Voltage: 2.630
   [2] Voltage: 2.868
 

 

 
 