适用场景

  • 以太网协议。IEEE 802.3
  • CRC或帧检查序列

问题解答

  • 收到损坏的帧后、ONTAP 会报告CRC错误。

  • ifstat 输出和AutoSupport 部分:

::> system node run -node node-name ifstat e0c 
-- interface  e0c  (7 days, 18 hours, 10 minutes, 41 seconds) -- 
RECEIVE 
 Total frames:    508k | Frames/second:     1  | Total bytes:   37009k 
 Bytes/second:     55  | Total errors:   12117 | Errors/minute:     0 
 Total discards:    0  | Discards/minute:   0  | Multi/broadcast: 1280k 
 Non-primary u/c:   0  | CRC errors:     12117 | Runt frames:       0 
 Long frames:       0  | Length errors:     0  | Alignment errors:  0 
 No buffer:         0  | Pause:             0  | Jumbo:             0 
 ...

  • 事件消息和EMS AutoSupport 消息: 

Wed Jun 30 02:38:27 CEST [node-name: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0c on node node-name is reporting a high number of observed hardware errors, possibly CRC errors.

  • 如果1000个帧中的帧数超过1个、则ONTAP 会在事件消息和EMS AutoSupport 消息中报告CRC错误。 

追加信息

  • CRC错误通常是由硬件故障或硬件不兼容引起的 
  • 网络交换机可能愿意转发错误的CRC帧
  • 数据包跟踪不有用 

 