跳转到主内容

AFF-A900和FAS9500的CPU VRD温度传感器读数错误

Views:
9
Visibility:
Public
Votes:
0
Category:
aff-series<a>2009337602</a>
Specialty:
hw
Last Updated:

 

适用场景

  • AFF-A900
  • FAS9500
  • ONTAP 9

问题描述

  • ONTAP错误地读取了CPU1或CPU2 VRD温度传感器并报告为0度、从而触发机箱低温警报。 
    • EMS日志:
      • Wed Oct 19 01:48:30 -0400 [Node_Name: env_mgr: monitor.chassisTemperature.cool:alert]: Chassis temperature is too cool: CPU2 VRD Temp is critical low (0 C).
    • BMC系统事件日志:

Record 1527: Sat Mar 04 00:32:01.076611 2023 [IPMI.notice]: 0513 | 02 | EVT: 01500005 | CPU2_VRD_Temp | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 5.000
Record 1528: Sat Mar 04 00:32:01.078001 2023 [IPMI.notice]: 0514 | 02 | EVT: 01520000 | CPU2_VRD_Temp | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.000

Record 1963: Mon Apr 24 18:13:18.996830 2023 [IPMI.notice]: 06b9 | 02 | EVT: 01500005 | CPU1_VRD_Temp | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 5.000
Record 1964: Mon Apr 24 18:13:18.998197 2023 [IPMI.notice]: 06ba | 02 | EVT: 01520000 | CPU1_VRD_Temp | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.000

Record 1978: Wed Apr 26 11:38:01.061589 2023 [IPMI.notice]: 06c7 | 02 | EVT: 6f02ffff | PSU1_Status | Assertion Event, "Fault"
Record 1979: Wed Apr 26 11:38:01.139064 2023 [IPMI.notice]: 06c8 | 02 | EVT: 6f02ffff | PSU3_Status | Assertion Event, "Fault"
Record 1980: Wed Apr 26 11:38:05.910595 2023 [IPMI.notice]: 06c9 | 02 | EVT: 6f02ffff | Fan3_Status | Assertion Event, "Fault"

  • 警报将在几秒钟后清除:
    • EMS日志:
      • Wed Oct 19 01:48:31 -0400 [Node_Name: env_mgr: monitor.chassisTemperature.ok:notice]: Chassis temperature is ok.

    • BMC系统事件日志:

Record 1981: Wed Apr 26 11:38:05.973490 2023 [IPMI.notice]: 06ca | 02 | EVT: ef02ffff | PSU1_Status | Deassertion Event, "Fault"
Record 1982: Wed Apr 26 11:38:06.058606 2023 [IPMI.notice]: 06cb | 02 | EVT: ef02ffff | PSU3_Status | Deassertion Event, "Fault"
Record 1983: Wed Apr 26 11:38:09.932151 2023 [IPMI.notice]: 06cc | 02 | EVT: ef02ffff | Fan3_Status | Deassertion Event, "Fault"

  • 其他传感器(PSU、风扇、PCM)可能会继续断言和断言"Fault"(故障)、系统风扇速度会在高电平和非临界电平之间波动。

Record 1938: Fri Apr 21 04:10:21.983012 2023 [IPMI.notice]: 06a0 | 02 | EVT: 81598aff | Fan1_Speed1 | Deassertion Event, "Upper Critical going high" | Reading: 8280.000 | Threshold: 15300.000
Record 1939: Fri Apr 21 04:10:21.987010 2023 [IPMI.notice]: 06a1 | 02 | EVT: 81578ad9 | Fan1_Speed1 | Deassertion Event, "Upper Non-critical going high" | Reading: 8280.000 | Threshold: 13020.000
Record 1940: Fri Apr 21 04:10:21.989607 2023 [IPMI.notice]: 06a2 | 02 | EVT: 81598bff | Fan1_Speed2 | Deassertion Event, "Upper Critical going high" | Reading: 8340.000 | Threshold: 15300.000
Record 1941: Fri Apr 21 04:10:21.991062 2023 [IPMI.notice]: 06a3 | 02 | EVT: 81578bd9 | Fan1_Speed2 | Deassertion Event, "Upper Non-critical going high" | Reading: 8340.000 | Threshold: 13020.000
Record 1942: Fri Apr 21 04:10:22.001742 2023 [IPMI.notice]: 06a4 | 02 | EVT: 81598aff | Fan1_Speed3 | Deassertion Event, "Upper Critical going high" | Reading: 8280.000 | Threshold: 15300.000
Record 1943: Fri Apr 21 04:10:22.003202 2023 [IPMI.notice]: 06a5 | 02 | EVT: 81578ad9 | Fan1_Speed3 | Deassertion Event, "Upper Non-critical going high" | Reading: 8280.000 | Threshold: 13020.000
Record 1944: Fri Apr 21 04:10:22.004990 2023 [IPMI.notice]: 06a6 | 02 | EVT: 81598aff | Fan1_Speed4 | Deassertion Event, "Upper Critical going high" | Reading: 8280.000 | Threshold: 15300.000
Record 1945: Fri Apr 21 04:10:22.006297 2023 [IPMI.notice]: 06a7 | 02 | EVT: 81578ad9 | Fan1_Speed4 | Deassertion Event, "Upper Non-critical going high" | Reading: 8280.000 | Threshold: 13020.000

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.