跳转到主内容

由于"LED_Box_Temp1"传感器中存在临界温度问题描述 、AFF A800可能会触发环境关闭

Views:
36
Visibility:
Public
Votes:
0
Category:
aff-series<a>BMC</a><a>AFF</a><a>AFF-A800</a><a>1101871</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF-A800
  • BMC 10.2P2或更早版本

问题描述

  • 由于"LED_Box_Temp1"中的临界温度问题描述 、AFF A800可能会触发环境关闭
  • BMC固件版本为10.2P2或更早版本。

在事件日志中、我们可以找到几条指向LED_Box_Temp1传感器的记录:

    Record 1889: Sun Dec 01 23:34:31.600000 2019 [IPMI.notice]: 0033 | 02 | EVT: 01572d2a | LED_Board_Temp1 | Assertion Event, "Upper Non-critical going high" | Reading: 45.000 | Threshold: 42.000
    Record 1890: Sun Dec 01 23:34:31.610000 2019 [IPMI.notice]: 0034 | 02 | EVT: 01592d2d | LED_Board_Temp1 | Assertion Event, "Upper Critical going high" | Reading: 45.000 | Threshold: 45.000
    Record 1891: Sun Dec 01 23:34:34.640000 2019 [IPMI.notice]: 0035 | 02 | EVT: 8159182d | LED_Board_Temp1 | Deassertion Event, "Upper Critical going high" | Reading: 24.000 | Threshold: 45.000
    Record 1892: Sun Dec 01 23:34:34.640000 2019 [IPMI.notice]: 0036 | 02 | EVT: 8157182a | LED_Board_Temp1 | Deassertion Event, "Upper Non-critical going high" | Reading: 24.000 | Threshold: 42.000
    Record 1893: Sun Dec 01 23:34:54.710000 2019 [IPMI.emergency]: env_mgr trigger OS halt:Temperature critical
    Record 1894: Sun Dec 01 23:35:34.000000 2019 [IPMI.notice]: 0037 | 02 | EVT: 6f406fff | Sensor 255 | Assertion Event, "Storage OS stop/shutdown"
    Record 1895: Sun Dec 01 23:35:35.000000 2019 [Controller.notice]: Appliance user command halt.
    Record 1896: Sun Dec 01 23:35:34.830000 2019 [IPMI Event.critical]: System power down
    Record 1897: Sun Dec 01 23:35:34.840000 2019 [IPMI.emergency]: Data ONTAP initiated shutdown
    Record 1898: Sun Dec 01 23:35:34.850000 2019 [IPMI.notice]: 0038 | 02 | EVT: 6f00ffff | Power_Event | Assertion Event, "Power off/down"


不久后、 控制台日志显示ONTAP OS触发的环境关闭:

    Dec 02 00:34:45 [node_name1:monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Ambient temperature is critical high. System will be shutdown immediately
    Dec 02 00:35:05 [node_name1:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)
    Waiting for PIDS:  1987.
    Terminated
    .
    Uptime: 111d13h47m10s
    System powering down...

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.