跳转到主内容

Exciting new changes are coming to the Knowledge Base site soon!
Starting April 4, 2023, you will notice Support-Specific categorization and improvements to the search filters on the site. In May, we will be launching a new and enhanced Site UI and Navigation. To know more, read our Knowledge Article.

添加第二个 NS224 磁盘架会将第一个磁盘架 ID 更改为序列号

Views:
47
Visibility:
Public
Votes:
0
Category:
disk-shelves<a>磁盘架 ID</a><a>NS224</a><a>2008530052</a>
Specialty:
core
Last Updated:

适用场景

  • NS224
  • ONTAP 9

问题描述

  • 将另一个 NS224 磁盘架添加到现有堆栈时,启动速度较慢,首先显示错误的 ID 0 ,稍后显示一些无法读取的字符。
  • 几分钟后,添加的磁盘架 NS224 将显示正确的磁盘架 ID 1 。
  • storage shelf showID 为 0 的先前现有磁盘架的 " " 输出将名称从 "1.0" 更改为 s/n "1.SHFHUXXXXXXXXXXXX" 。

::> storage shelf show
                            Module Operational
    Shelf Name Shelf ID Serial Number   Model     Type   Status
----------------- -------- --------------- ----------- ------ -----------
1.SHFHUXXXXXXXXXX    0 SHFHUXXXXXXXXXX NS224NSM100 NSM100 Normal
        1.1     1 SHFHUYYYYYYYYYY NS224NSM100 NSM100 Normal
2 entries were displayed.

::> storage disk show
           Usable       Disk   Container   Container
Disk           Size Shelf Bay Type   Type     Name                     Owner
---------------- ---------- ----- --- ------- ----------- ---------                   --------
Info: This cluster has partitioned disks. To get a complete list of spare disk capacity use "storage aggregate show-spare-disks".
1.0.0         6.99TB    0   0 SSD-NVM shared    aggr_name_1, aggr_name_2           node_name_2

1.0.5         6.99TB    0   5 SSD-NVM shared    aggr0_name_1, aggr_name_1, aggr_name_2    node_name_2
1.SHFHUXXXXXXXXXX.6  6.99TB    0   6 SSD-NVM shared    aggr0_name_2, aggr_name_1, aggr_name_2    node_name_1

1.SHFHUXXXXXXXXXX.11 6.99TB    0  11 SSD-NVM shared    aggr0_name_2, aggr_name_1, aggr_name_2    node_name_1
1.0.12         6.99TB    0  12 SSD-NVM shared    aggr0_name_1, aggr_name_1, aggr_name_2    node_name_2

1.0.17         6.99TB    0  17 SSD-NVM shared    aggr0_name_1, aggr_name_1, aggr_name_2    node_name_2
1.SHFHUXXXXXXXXXX.18 6.99TB    0  18 SSD-NVM shared    aggr0_name_2, aggr_name_1, aggr_name_2    node_name_1

1.SHFHUXXXXXXXXXX.23 6.99TB    0  23 SSD-NVM shared    -                       node_name_1
1.1.0         6.99TB    1   0 SSD-NVM spare     Pool0                     node_name_2

1.1.5         6.99TB    1   5 SSD-NVM spare     Pool0                     node_name_2
1.SHFHUXXXXXXXXXX.18 6.99TB    1  18 SSD-NVM spare     Pool0                     node_name_1

1.SHFHUXXXXXXXXXX.23 6.99TB    1  23 SSD-NVM spare     Pool0                     node_name_1
36 entries were displayed.

  • 在节点级别的 CLI 中,只有一个节点报告 " 错误 " 的磁盘架 ID :

node_name_1> storage show shelf
Shelf name:   0x.shelfSHFHUXXXXXXXXXX
Shelf id:    0
Channel:     0x
Module:     A

Shelf name:   0x.shelfSHFHUXXXXXXXXXX
Shelf id:    0
Channel:     0x
Module:     B


node_name_2> storage show shelf
Shelf name:   0x.shelf0
Shelf id:    0
Channel:     0x
Module:     A

Shelf name:   0x.shelf0
Shelf id:    0
Channel:     0x
Module:     B

 

Sign in to view the entire content of this KB article.