跳转到主内容

节点重新启动、并显示机箱温度过高关闭紧急错误

Views:
24
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • AFF A400
  • FAS8700和FAS8300
  • BMC FW 13.4及更早版本

问题描述

  • 节点将在关闭后重新启动。
  • 多个传感器值显示 na

PVCCIN_CPU0 | na | Volts | na | na | 0.010 | 0.020 | 2.460 | 2.470 | na
PVCCIN_CPU1 | na | Volts | na | na | 0.010 | 0.020 | 2.460 | 2.470 | na
PVDDQ_ABC | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
PVDDQ_DEF | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
PVDDQ_GHI | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
PVDDQ_KLM | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
P1V05_PCH | na | Volts | na | na | 0.940 | 0.992 | 1.100 | 1.147 | na
...
CX5_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
CX5_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
...
RiserL_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserL_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp3 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp4 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp3 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp4 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
CPU0_Temp | na | degrees C | na | na | na | na | 90.000 | 100.000 | na
CPU1_Temp | na | degrees C | na | na | na | na | 90.000 | 100.000 | na
Mezz_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
Mezz_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 54.000 | 57.000 | na

  • 多个温度传感器在 sel elist中显示状态"nc":

02/17/2022 | 16:57:53 | Temperature LED2_Temp | Lower Non-critical going low | Reading 4 < Threshold 3 degrees C
02/17/2022 | 16:58:00 | Temperature LED1_Temp | Lower Non-critical going low | Reading 4 < Threshold 3 degrees C
02/17/2022 | 17:48:22 | Temperature MP_Temp3 | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:49:40 | Temperature System_Inlet | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:49:55 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:50:09 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 6 < Threshold 5 degrees C
02/17/2022 | 17:50:15 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:50:40 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 6 < Threshold 5 degrees C

  • 重新启动前显示的内容示例:
Nov 11, 2020 07:00:41  0100 HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR
Nov 11, 2020 07:34:52  0100 HA Group Notification (CHASSIS OVER TEMPERATURE SHUTDOWN) EMERGENCY
Nov 11, 2020 10:16:20  0100 HA Group Notification (BATTERY ('Bat Temp' unreadable)) EMERGENCY
Nov 11, 2020 10:16:55  0100 HA Group Notification (BATTERY ('Bat Volt' unreadable)) EMERGENCY
Nov 11, 2020 10:17:07  0100 HA Group Notification (BATTERY ('Bat Curr' unreadable)) EMERGENCY
Nov 11, 2020 10:17:18  0100 HA Group Notification (BATTERY ('Bat Full Cap' unreadable)) EMERGENCY
Nov 11, 2020 10:17:40  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan1_1) ERROR
Nov 11, 2020 10:17:54  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan2_1) ERROR
Nov 11, 2020 10:18:08  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan2_2) ERROR
Nov 11, 2020 10:18:19  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan3_1) ERROR
Nov 11, 2020 10:18:30  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan3_2) ERROR
 

 

 
 
Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support