跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

节点重新启动、并显示机箱温度过高关闭紧急错误

Views:
26
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • AFF A400
  • FAS8700和FAS8300
  • BMC FW 13.4及更早版本

问题描述

  • 节点将在关闭后重新启动。
  • 多个传感器值显示 na

PVCCIN_CPU0 | na | Volts | na | na | 0.010 | 0.020 | 2.460 | 2.470 | na
PVCCIN_CPU1 | na | Volts | na | na | 0.010 | 0.020 | 2.460 | 2.470 | na
PVDDQ_ABC | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
PVDDQ_DEF | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
PVDDQ_GHI | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
PVDDQ_KLM | na | Volts | na | na | 0.014 | 0.021 | 1.711 | 1.732 | na
P1V05_PCH | na | Volts | na | na | 0.940 | 0.992 | 1.100 | 1.147 | na
...
CX5_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
CX5_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
...
RiserL_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserL_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp3 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserM_Temp4 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp3 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
RiserR_Temp4 | na | degrees C | na | na | 0.000 | 5.000 | 60.000 | 70.000 | na
CPU0_Temp | na | degrees C | na | na | na | na | 90.000 | 100.000 | na
CPU1_Temp | na | degrees C | na | na | na | na | 90.000 | 100.000 | na
Mezz_Temp1 | na | degrees C | na | na | 0.000 | 5.000 | 80.000 | 85.000 | na
Mezz_Temp2 | na | degrees C | na | na | 0.000 | 5.000 | 54.000 | 57.000 | na

  • 多个温度传感器在 sel elist中显示状态"nc":

02/17/2022 | 16:57:53 | Temperature LED2_Temp | Lower Non-critical going low | Reading 4 < Threshold 3 degrees C
02/17/2022 | 16:58:00 | Temperature LED1_Temp | Lower Non-critical going low | Reading 4 < Threshold 3 degrees C
02/17/2022 | 17:48:22 | Temperature MP_Temp3 | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:49:40 | Temperature System_Inlet | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:49:55 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:50:09 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 6 < Threshold 5 degrees C
02/17/2022 | 17:50:15 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 5 < Threshold 5 degrees C
02/17/2022 | 17:50:40 | Temperature MP_Temp1 | Lower Non-critical going low | Reading 6 < Threshold 5 degrees C

  • 重新启动前显示的内容示例:
Nov 11, 2020 07:00:41  0100 HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR
Nov 11, 2020 07:34:52  0100 HA Group Notification (CHASSIS OVER TEMPERATURE SHUTDOWN) EMERGENCY
Nov 11, 2020 10:16:20  0100 HA Group Notification (BATTERY ('Bat Temp' unreadable)) EMERGENCY
Nov 11, 2020 10:16:55  0100 HA Group Notification (BATTERY ('Bat Volt' unreadable)) EMERGENCY
Nov 11, 2020 10:17:07  0100 HA Group Notification (BATTERY ('Bat Curr' unreadable)) EMERGENCY
Nov 11, 2020 10:17:18  0100 HA Group Notification (BATTERY ('Bat Full Cap' unreadable)) EMERGENCY
Nov 11, 2020 10:17:40  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan1_1) ERROR
Nov 11, 2020 10:17:54  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan2_1) ERROR
Nov 11, 2020 10:18:08  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan2_2) ERROR
Nov 11, 2020 10:18:19  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan3_1) ERROR
Nov 11, 2020 10:18:30  0100 HA Group Notification (CHASSIS FAN FRU FAILED: Fan3_2) ERROR
 

 

 
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device