问题描述

  • 一个节点无法重复启动:
Press Esc-T or Ctrl-D to exit
Waiting for reservations to clear
Waiting for reservations to clear
Waiting for reservations to clear
...
  • 配对节点中的HA互连链路已启动、但IC RDMA已关闭:

::> set advanced
::*> system ha interconnect status show
                       Node: node_name
              Link 0 Status: up
              Link 1 Status: up
           Is Link 0 Active: true
           Is Link 1 Active: true
         IC RDMA Connection: down

  • 两个节点中的集群端口均已启动:

*> sysconfig -v
...
slot 0: 25G Ethernet Controller CX5
    e0c MAC Address:    XX:XX:XX:XX:XX:XX (auto-25g_cr-fd-up)
        SFP Vendor:         Amphenol
        SFP Part Number:    NDCCGF-N103
        SFP Serial Number:  XXXXXXXXXXXXXX
    e0d MAC Address:    XX:XX:XX:XX:XX:XX (auto-25g_cr-fd-up)
        SFP Vendor:         Amphenol
        SFP Part Number:    NDCCGF-N103
        SFP Serial Number:  XXXXXXXXXXXXXX

  • 两个节点均已禁用存储故障转移:

[node_name: statd: cf.takeover.disabled:alert]: HA mode, but takeover of partner is disabled due to reason : HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support.

 