跳转到主内容

NetApp wins prestigious Coveo Relevance Pinnacle Award. Learn more!

INSIGHT Japan :2023年 1月25日(水)ANAインターコンチネンタルホテル開催 へ参加・申込を行う

AF-A400 不会检测导致故障转移的配对节点

Views:
3
Visibility:
Public
Votes:
0
Category:
aff-series<a>接管</a><a>检测信号</a><a>2008800192</a>
Specialty:
hw
Last Updated:

适用场景

  • AFF A400
  • FAS 8300
  • FAS 8700

问题描述

  • 未报告崩溃或 NMI 的接管。
  • 未触发核心文件。
  • EMS 日志显示由于未检测到检测信号而发生的接管。示例:

[Nodeb: kernel: netif.linkDown:info]: Ethernet e0a: Link down, check cable.
[Nodeb: kernel: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
[Nodeb: wafl_exempt17: nvmm.mirror.aborting:debug]: mirror of sysid 1, partner_type HA Partner and mirror state NVMM_MIRROR_ONLINE is aborted because of reason NVMM_ERR_IO.
...
[Nodeb: cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.
[Nodeb: cf_takeover: cf.fm.takeoverStarted:notice]: Failover monitor: takeover started
...

  • 交还后未发现问题。

 