适用场景

  • ONTAP 9
  • AFF-A250

问题描述

  • AFF-A250 节点报告 CHASSIS POWER SUPPLY DEGRADED CHASSIS OVER TEMPERATURE 警报。
  • 使用问题描述 的节点中的PSU传感器不可读、但配对节点无法读取。示例:

事件日志:

[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Fault is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Warning is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Out Fault is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Inlet is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Hot is Unreadable
[n02: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU2, PSU1.
[n02: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2, PSU1.
 
SP 最新 IPMI :
 
PSU1_Inlet       | na         | degrees C  | na    | na        | 0.000     | 0.000     | 58.000    | 63.000    | na       
PSU1_Hot         | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU1_FB_Hot      | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU1_Fan         | na         | RPM        | na    | na        | 800.000   | 1200.000  | na        | na        | na       
PSU1_status      | na         | discrete   | na    | na        | na        | na        | na        | na        | na       
PSU2_Inlet       | na         | degrees C  | na    | na        | 0.000     | 0.000     | 58.000    | 63.000    | na       
PSU2_Hot         | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU2_FB_Hot      | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU2_Fan         | na         | RPM        | na    | na        | 800.000   | 1200.000  | na        | na        | na       
PSU2_status      | na         | discrete   | na    | na        | na        | na        | na        | na        | na  