适用场景

  • ONTAP 9
  • AFF-A250

问题描述

  • AFF-A250 节点报告 CHASSIS POWER SUPPLY DEGRADED CHASSIS OVER TEMPERATURE 警报。
  • 使用问题描述 的节点中的PSU传感器不可读、但配对节点无法读取。示例:

事件日志:

[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Fault is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Warning is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Out Fault is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Inlet is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Hot is Unreadable
[n02: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU2, PSU1.
[n02: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2, PSU1.
 
SP 最新 IPMI :
 
PSU1_Inlet       | na         | degrees C  | na    | na        | 0.000     | 0.000     | 58.000    | 63.000    | na       
PSU1_Hot         | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU1_FB_Hot      | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU1_Fan         | na         | RPM        | na    | na        | 800.000   | 1200.000  | na        | na        | na       
PSU1_status      | na         | discrete   | na    | na        | na        | na        | na        | na        | na       
PSU2_Inlet       | na         | degrees C  | na    | na        | 0.000     | 0.000     | 58.000    | 63.000    | na       
PSU2_Hot         | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU2_FB_Hot      | na         | degrees C  | na    | na        | 0.000     | 0.000     | 100.000   | 105.000   | na       
PSU2_Fan         | na         | RPM        | na    | na        | 800.000   | 1200.000  | na        | na        | na       
PSU2_status      | na         | discrete   | na    | na        | na        | na        | na        | na        | na  

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.