跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

由于bootarg.pegasus.nvmefor.storage_ports配置不当、在更换启动设备后"进入FM状态:5"

Views:
Visibility:
Public
Votes:
0
Category:
aff-series<a>FSE</a><a>2009066800</a>
Specialty:
hw
Last Updated:

适用场景

  • NS224 磁盘架
  • ONTAP 9

问题描述

在对 [1] AFF 型号执行启动设备更换操作步骤 后,节点将返回到等待交还状态;但是,控制台上会持续显示以下消息。

Entering FM state:5 because mbFound:0 local in headswap:0

查看 clustershell 中的 storage failover show 输出会将状态问题描述 显示为 "Kernel loaded" :

                Takeover
Node       Partner     Possible State Description
-------------- -------------- -------- -------------------------------------
cluster1-01   cluster1-02 true    Connected to cluster1-02
cluster1-02   cluster1-01 true    Kernel loaded
2 entries were displayed.

 