跳转到主内容

无法访问ESXi数据存储库、并显示错误"device enteres the all paths down state"

Views:
38
Visibility:
Public
Votes:
2
Category:
ontap-9
Specialty:
san
Last Updated:

适用场景

  • VMware ESXi所有版本 
  • ONTAP 9

问题描述

  • 主机报告所有路径均已关闭、并且无法访问存储
  • 在主机日志中显示错误消息:
    • cpu34:33313)StorageApdHandler: 982: APD Handle Created with lock[StorageApd-0x43041149xxb0]
    • [APDCorrelator]:[vob.storage.apd.start] Device or filesystem with identifier [x] has entered the All Paths Down state.
    • [APDCorrelator]:[esx.problem.storage.apd.start] Device or filesystem with identifier [x] has entered the All Paths Down state.
  • ESX 数据存储库发现存储设备的大量路径冗余 naa.600a0980383x363644xxf41354x6773 已降级。路径 vmxba1:C0:Tx44:L100 已关闭。受影响的数据存储库: EsxHxxPrdVxiOs900_ushouxxor1011
  • 受影响主机启动程序的EMS日志中观察到的以下登录事件:

Tue Nov 14 07:08:14 -0600 [ushouxxtor10-09: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '2a' by initiator port: '20:0x:0x:25:bx:02:a0:76' address 0xe80xx6. The target virtual port is: 'NetApp FC Target Port (LPe32000) ushoxxtor1011-EsxVxi:ushoxxtor10-0x_fx_lif_1'.
Tue Nov 14 07:08:14 -0600 [ushouxxor10-09: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '4a' by initiator port: '20:0x:0x:2x:bx:02:a0:76' address 0xe80xx6. The target virtual port is: 'NetApp FC Target Port (LPe32000) ushoxxtor1011-EsxVxi:ushoustor10-0x_fx_lif_3

  • IO WQE 在EMS日志中观察到扩展状态为16的错误:

Tue Nov 14 07:08:19 -0600 [ushxxstor10-09: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:2b IO WQE failure, Handle 0x3, Type 8, S_ID: C8xx92, VPI: 279, OX_ID: 472A, Status 0x3 Ext_Status 0x16

  • vobd 主机日志路径已从观察到的死错误中更改:

2023-11-14T14:16:43.461Z: [scsiCorrelator] 6940447943826us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T14x:L100 changed state from dead
2023-11-14T14:16:43.485Z: [scsiCorrelator] 6940447967687us: [vob.scsi.scsipath.add] Add path: vmhba2:C0:T16x:L100
2023-11-14T14:16:43.492Z: [scsiCorrelator] 6940447974351us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T16x:L100 changed state from dead
2023-11-14T14:16:43.540Z: [scsiCorrelator] 6940448022605us: [vob.scsi.scsipath.add] Add path: vmhba2:C0:T14x:L100
2023-11-14T14:16:43.551Z: [scsiCorrelator] 6940448033745us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T14x:L100 changed state from dead

  • 可以验证以下步骤、这些步骤可能会触发存储设备的APD状态: 
    • 可能的网络结构问题
    • 验证端到端连接
    • 验证所有终端端口状态
    • 检查潜在性能问题

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.