交换机端口 "x" 运行状况不正常 / 交换机端口 "x" 出现错误
适用场景
- 光纤通道协议( FCP )
- SAN
- Brocade
- Cisco
问题描述
Brocade/Cisco 中的交换机端口运行状况不正常,或者交换机端口出现多个错误。
- 交换机日志( Brocade ):
2020/03/10-10:20:06, [C4-1010], 13033, SLOT X CHASSIS, CRITICAL, Brocade_XX-X, X,X: Above normal hardware errors were observed: fault1:0x64, fault2:0x64 thresh2:0xb0000064.
2019/06/01-08:39:16, [C3-1014], 74, CHASSIS, WARNING, xxxxx, Link Reset on Port Sx,Px(x) vc_no=0 crd(s)lost=x auto trigge
- 交换机日志( Cisco ):
2020 Aug 25 04:26:00 %PORT-5-IF_DOWN_NOS_RCVD: %$VSAN 451%$ Interface fc1/13 is down (NOS received)
- 低 Tx 或 Rx 功率值:
RX Power: -40.0 dBm (0.1 uW) 31.6 uW 1258.9 uW 31.6 uW 794.0 uW
TX Power: -2.2 dBm (600.1 uW) 126.0 uW 1258.9 uW 251.0 uW 794.0 uW
- 性能问题:
2020/05/19-20:08:21, [AN-1010], 687622, FID 128, WARNING, XXXX, Severe latency bottleneck detected at slot 0 port