跳转到主内容

Brocade 交换机中标记为慢速排污设备的端口

Views:
46
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • Brocade Fabric OS 7.4及更高版本

问题描述

  • 端口在 Brocade 交换机中标记为“低排放设备”、并通过运行来验证 sddquarantine --show

示例

----- SDDQ Data ------
----------------------------------------------------------
Ports marked as Slow Drain Quarantined in the Local Switch:
           2/8
----------------------------------------------------------
Online Quarantined Devices across the fabric
----------------------------------------------------------
Port Index |   PID   |            PWWN
----------------------------------------------------------
     174    | 01ae01 | 00:00:00:00:00:00:00:00
----------------------------------------------------------
Configured Limit=10 Quarantined count in chassis=1

  • errdump -a还可以从输出中验证时间点:

示例

2020/06/04-09:25:22, [MAPS-1022], 74058, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) has been marked as Slow Drain Device.

 