Brocade 交换机中标记为慢速排污设备的端口
适用场景
- Brocade Fabric OS 7.4及更高版本
问题描述
- 端口在 Brocade 交换机中标记为“低排放设备”、并通过运行来验证
sddquarantine --show
示例:
----- SDDQ Data ------
----------------------------------------------------------
Ports marked as Slow Drain Quarantined in the Local Switch:
2/8
----------------------------------------------------------
Online Quarantined Devices across the fabric
----------------------------------------------------------
Port Index | PID | PWWN
----------------------------------------------------------
174 | 01ae01 | 00:00:00:00:00:00:00:00
----------------------------------------------------------
Configured Limit=10 Quarantined count in chassis=1
errdump -a
还可以从输出中验证时间点:
示例:
2020/06/04-09:25:22, [MAPS-1022], 74058, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) has been marked as Slow Drain Device.
- 在映射清除状态之前、端口状态将保持隔离状态
2020/06/04-09:26:22, [MAPS-1003], 74059, SLOT 7 | FID 128, WARNING, SANCORESC10, CASTNASCLP01-03_0e, F-Port 2/8, Condition=ALL_PORTS(DEV_LATENCY_IMPACT==IO_LATENCY_CLEAR), Current Value:[DEV_LATENCY_IMPACT, IO_LATENCY_CLEAR], RuleName=ALL_PORTS_IO_LATENCY_CLEAR, Dashboard Category=Fabric Performance Impact.
2020/06/04-09:36:22, [NS-1018], 74060, SLOT 7 | FID 128, INFO, SANCORESWITCH, Domain 10, Port index 24, All devices zoned with the slow drain device 0x0a1800 have been unquarantined.
2020/06/04-09:36:22, [MAPS-1025], 74062, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) removed from the Slow Drain Device Quarantine Group.