问题描述

  • 在Brocade交换机上观察到多个链路封板、同时两个EX端口都关闭、从而导致网络结构中断、因为多个域不可重复。
  • 此类事件可在 Fabriclog 输出下的交换机日志中观察为"BF–Build Fabric "事件、状态将通过网络结构交换机上的ISL端口传递、如以下代码片段所示:

Switch 0; Tue Sep 13 11:03:24 2022 IST (GMT+5:30)
11:03:24.283511 BF Rcv                    A2,P3  A2,P3  46   0xaa1 
11:03:24.283918 BF sending ACC                F0,P3  F0,P3  46   0xaa1 
11:03:24.284541 *BF Flood                   F0,NA  F0,NA  NA   NA   
11:03:24.284658 *BF Send:iu=0x19dce2b0            F0,P3  F0,P3  0    0x1b71
11:03:24.284758 *BF Send:iu=0x19dd28a0            F0,P3  F0,P3  38   0x7e37
11:03:24.285039 *BF Send:iu=0x19dd2b90            F0,P3  F0,P3  96   0x5c42
11:03:24.288801 BF ACC Rcv                  F0,P3  F0,P3  38   0x7e37
11:03:24.288818 BF ACC Rcv                  F0,P3  F0,P3  96   0x5c42
11:03:24.289342 SCN Domain 102 invalid            F0,NA  F0,NA  NA   NA   
11:03:24.290925 BF ACC Rcv                  F0,P3  F0,P3  0    0x1b71
11:03:25.401576 SCN Domain 1 reachable            F0,NA  F0,NA  NA   NA   
11:03:41.566052 SCN Domain 102 valid             A2,NA  A2,NA  NA   NA   
11:03:41.616345 SCN Domain 1 available            A2,NA  A2,NA  NA   NA   
11:03:41.623640 SCN Domain 200 available           A2,NA  A2,NA  NA   NA   
11:03:41.629084 SCN Domain 1 available            A2,NA  A2,NA  NA   NA   
11:03:41.653521 BF Rcv                    A2,P3  A2,P3  46   0xb6f 
11:03:41.653914 BF sending ACC                F0,P3  F0,P3  46   0xb6f 
11:03:41.654520 *BF Flood                   F0,NA  F0,NA  NA   NA   
11:03:41.654615 *BF Send:iu=0x19dce2b0            F0,P3  F0,P3  0    0x609d
11:03:41.654709 *BF Send:iu=0x19dcde90            F0,P3  F0,P3  38   0x6bf9
11:03:41.655198 *BF Send:iu=0x19dd1d90            F0,P3  F0,P3  96   0x786b
11:03:41.665608 BF ACC Rcv                  F0,P3  F0,P3  38   0x6bf9
11:03:41.665624 BF ACC Rcv                  F0,P3  F0,P3  0    0x609d
11:03:41.665633 BF ACC Rcv                  F0,P3  F0,P3  96   0x786b
               

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.