跳转到主内容

Brocade交换机上报告了机箱警告C4-1006和严重C4-1010消息

Views:
61
Visibility:
Public
Votes:
1
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

状态信息

适用场景

  • Brocade (DCX) 
  • X6主管

问题描述

  • 交换机上的一个端口刀片式服务器进入禁用状态、并在errdump下报告以下错误:

2020/01/22-19:07:06, [C4-1010], 433, SLOT 2 | CHASSIS, CRITICAL, DCX, S12,C0: Above normal hardware errors were observed: fault1:0x1, fault2:0x64 thresh2:0xb0000064.
2020/01/22-19:20:41, [C4-1006], 434, SLOT 2 | CHASSIS, WARNING, DCX, S12,C0: Various non-critical hardware errors were observed: fault1:0xa, fault2:0x64 thresh1:0xa000000a.

  • 在上面的示例中、插槽2 CP报告了此错误、它正在监控交换机、但报告插槽12 (S12)芯片0上的刀片式服务器上存在问题描述。

 

  • HAshow 将当前活动CP报告为插槽2:

Local CP (Slot 2, CP1): Active, Warm Recovered
Remote CP (Slot 1, CP0): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized

  • slotshow -m 显示受影响插槽(此处的插槽12根据上述日志段)上的刀片式服务器运行状况良好。

slotshow -m:

Slot   Blade Type     ID    Model Name     Status 
--------------------------------------------------
  1     CP BLADE    175     CPX6           ENABLED
  2     CP BLADE    175     CPX6           ENABLED
  3     SW BLADE    178     FC32-48        ENABLED
  4     SW BLADE    178     FC32-48        ENABLED
  5     SW BLADE    178     FC32-48        ENABLED
  6     SW BLADE    178     FC32-48        ENABLED
  7     CORE BLADE  177     CR32-8         ENABLED
  8     CORE BLADE  177     CR32-8         ENABLED
  9     SW BLADE    178     FC32-48        ENABLED
 10     SW BLADE    178     FC32-48        ENABLED
 11     SW BLADE    178     FC32-48        ENABLED
 12     SW BLADE    178     FC32-48        ENABLED

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.