Brocade FC 端口脱机且处于 IN_Sync 状态
适用场景
- 所有 Brocade 硬件平台
- 所有 Brocade 网络结构操作系统( FOS )平台
问题描述
连接到终端设备(主机,存储, ATTO 等)的 Brocade 光纤通道端口正在从正常状态切换到不具有网络结构 WWPN 登录的 "in_sync" 状态:
正常
brocade_sw:admin> switchshow
switchName: brocade_sw
switchType: 118.1
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 6
switchId: fffc06
switchWwn: 10:xx:xx:xx:xx:xx:xx:xx
zoning: ON (ZONING_CONFIG)
switchBeacon: OFF
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================
0 0 060000 id 16G Online FC F-Port 21:00:00:0e:1e:e9:bc:93
1 1 060100 id 16G No_Light FC (POD license not assigned or reserved yet) Disabled (Persistent)
2 2 060200 id 16G Online FC F-Port 50:0a:09:81:03:b3:67:a0
3 3 060300 id 16G Online FC F-Port 10:00:00:90:fa:e6:c6:16
4 4 060400 id 16G No_Light FC (POD license not assigned or reserved yet) Disabled (Persistent)
5 5 060500 id 16G No_Light FC (POD license not assigned or reserved yet) Disabled (Persistent)
6 6 060600 -- 16G No_Module FC (POD license not assigned or reserved yet) Disabled (Persistent)
7 7 060700 -- 16G No_Module FC (POD license not assigned or reserved yet) Disabled (Persistent)
8 8 060800 id 16G Online FC F-Port 22:00:00:10:86:a5:0a:c0
已关闭:
brocade_sw:admin> switchshow
switchName: brocade_sw
switchType: 118.1
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 6
switchId: fffc06
switchWwn: 10:xx:xx:xx:xx:xx:xx:xx
zoning: ON (ZONING_CONFIG)
switchBeacon: OFF
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================
0 0 060000 id 16G Online FC F-Port 21:00:00:0e:1e:e9:bc:93
1 1 060100 id 16G No_Light FC (POD license not assigned or reserved yet) Disabled (Persistent)
2 2 060200 id 16G Online FC F-Port 50:0a:09:81:03:b3:67:a0
3 3 060300 id 16G Online FC F-Port 10:00:00:90:fa:e6:c6:16
4 4 060400 id 16G No_Light FC (POD license not assigned or reserved yet) Disabled (Persistent)
5 5 060500 id 16G No_Light FC (POD license not assigned or reserved yet) Disabled (Persistent)
6 6 060600 -- 16G No_Module FC (POD license not assigned or reserved yet) Disabled (Persistent)
7 7 060700 -- 16G No_Module FC (POD license not assigned or reserved yet) Disabled (Persistent)
8 8 060800 id 16G In_Sync FC
按照以下步骤隔离问题描述:
- 如果Tx和Rx值在最佳范围内、请验证 与连接到交换机端口的终端设备的端到端连接、包括电缆、配线板和端口速度。
- 如果在可能的硬件更换后未发现其他指示灯、请卸下、清洁并重新拔插终端设备SFP、电缆和配线板连接(如果适用)以及交换机SFP。
- 如果一切正常、并且问题描述仍然存在、请将其移至 交换机端的下一个可用端口并验证状态。