跳转到主内容

SwitchFanNotOperational_Alert—AutoSupport 消息

Views:
5
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • Cisco Nexus集群交换机
  • 对于运行状况监控器进程cshm、请致电home:SwitchFanNotOperational_Alert

事件摘要

如果未检测到风扇电源、并且风扇状态显示为非运行、则会发送SwitchFanNotOperational_Alert。 

验证

主叫事件

HA Group Notification from Node Name (Health Monitor process cshm: SwitchFanNotOperational_Alert[Switch Name(Switch Serial Number)/Fan Module-3]) ALERT

EMS日志

event log show -severity * -message-name callhome*

[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchFanNotOperational_Alert[Switch Name(Switch Serial Number)/Fan Module-3].

命令行

system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchFanNotOperational_Alert

            Node: Node01
          Monitor: cluster-switch
       Class of Alert: SwitchFanNotOperational_Alert
     Severity of Alert: Major
       Probable Cause: Out_of_service
Probable Cause Description: "Fan Module-3" on switch "Switch Name(Switch Name)" is not functioning properly.
      Possible Effect: Cooling of switch "Switch Name(Serial Number)" might be degraded.
     Corrective Actions: 1) Use the switch CLI to verify that the fan is functioning at the expected speed.                      2) Replace the fan, if it is not operational.

交换机日志输出:

switch_name# show environment fan detail

Fan:
---------------------------------------------------------------------------
Fan        Model         Hw    Direction     Status
---------------------------------------------------------------------------
Fan1(sys_fan1)  NXA-FAN-30CFM-F    --    back-to-front  Failure
Fan2(sys_fan2)  NXA-FAN-30CFM-F    --    back-to-front   Ok

Fan:
------------------------------------------------------------------
Fan Name      Fan Num   Fan Direction   Speed(%)  Speed(RPM)
------------------------------------------------------------------
Fan1(sys_fan1)    fan1   back-to-front   0     0
Fan1(sys_fan1)    fan2   back-to-front   100     11563

解决方法

如需进一步帮助、请联系Cisco技术支持中心。解决方案 可能需要更换部件。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.