跳转到主内容

Brocade 交换机中标记为慢速排污设备的端口

Views:
57
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • Brocade Fabric OS 7.4及更高版本

问题描述

  • 端口在 Brocade 交换机中标记为“低排放设备”、并通过运行来验证 sddquarantine --show

示例

----- SDDQ Data ------
----------------------------------------------------------
Ports marked as Slow Drain Quarantined in the Local Switch:
           2/8
----------------------------------------------------------
Online Quarantined Devices across the fabric
----------------------------------------------------------
Port Index |   PID   |            PWWN
----------------------------------------------------------
     174    | 01ae01 | 00:00:00:00:00:00:00:00
----------------------------------------------------------
Configured Limit=10 Quarantined count in chassis=1

  • errdump -a还可以从输出中验证时间点:

示例

2020/06/04-09:25:22, [MAPS-1022], 74058, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) has been marked as Slow Drain Device.

  • 在映射清除状态之前、端口状态将保持隔离状态

2020/06/04-09:26:22, [MAPS-1003], 74059, SLOT 7 | FID 128, WARNING, SANCORESC10, CASTNASCLP01-03_0e, F-Port 2/8, Condition=ALL_PORTS(DEV_LATENCY_IMPACT==IO_LATENCY_CLEAR), Current Value:[DEV_LATENCY_IMPACT, IO_LATENCY_CLEAR], RuleName=ALL_PORTS_IO_LATENCY_CLEAR, Dashboard Category=Fabric Performance Impact.

2020/06/04-09:36:22, [NS-1018], 74060, SLOT 7 | FID 128, INFO, SANCORESWITCH, Domain 10, Port index 24, All devices zoned with the slow drain device 0x0a1800 have been unquarantined.

2020/06/04-09:36:22, [MAPS-1025], 74062, SLOT 7 | FID 128, WARNING, SANCORESWITCH, Port 2/8 (Port index 24) removed from the Slow Drain Device Quarantine Group

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.