执行

执行

适用于

  • SAN
  • MetroCluster

说明

Brocade 6520 、 6510 、 6505 或 5100 交换机上报告的电源或风扇出现故障:

  • 报告错误的 PS :

psshow :

Power Supply #1 is OK
Airflow Direction : Portside Exhaust (Reverse)
Power Supply #2 is faulty*
* = No system control access to power supply.

  • 报告风扇故障:

fanshow        :
Fan 1 is Ok, speed is 4071 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4119 RPM
Fan 4 is Ok, speed is 18977 RPM
Fan 5 is Unknown

  • Brocade X6-4 和 Brocade X6-8 上报告的电源或风扇出现故障:

psshow        :

Power Supply #1 is OK
V10N18,   DUCXXXXXXHJ      ,23-0000161-01,A0,DELTA,ECXXXXXXX42     ,00,DUXXXX8N
Power Supply #2 is faulty
V10N22,   DUCXXXXXX1H      ,23-0000161-01,A0,DELTA,ECXXXXXXX42     ,00,DUXXXX2N

fanshow        :
Fan 1 is Ok, speed is 4067 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4067 RPM

 

Brocade X6-4 导向器:两个风扇组件(非端口端排气或进气)用于 1+1 冗余。每个组件包含 2 个风扇、总共 4 个。系统需要 4 个正常工作的风扇中的 3 个。一个风扇组件可以热插拔、但必须立即更换。

 

Brocade X6-8 Director :三个风扇组件、非端口端排气或进气、可实现 2+1 冗余。每个组件总共包含 2 个风扇,共 6 个。系统需要 6 个正常工作的风扇中的 5 个。一个风扇组件可以热插拔、但必须立即更换。

 