In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

集群交换机 CN1610 上出现错误的温度警告警报

Views:
22
Visibility:
Public
Votes:
0
Category:
data-ontap-8
Specialty:
hw
Last Updated:

适用于

  • CN1610 
  • Data ONTAP 8 7-模式
  • 集群模式 Data ONTAP 8.2
  • 集群模式 Data ONTAP 8.3

问题

AutoSupport EMS 消息示例:

Call home for Health Monitor process cshm: SwitchTemperatureWarn_Alert[switch_name/location].

  • CN1610 集群互连交换机可能会生成非常短暂的温度警告,不会记录在交换机日志中。
  • 此时,集群交换机运行状况监控器( Cluster Switch Health Monitor , CSHM )将生成温度警告警报。
  • 此时, CSHM 警报可能会出现,然后随着情况的持续存在而消失。
  • 温度警告可能并不表示交换机出现故障。它们只是表示交换机的温度发生了显著变化。