跳转到主内容

EMS报告由于存储端SFP出现故障、在FC端口上检测到链路中断

Views:
33
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2008914376.</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • 小型可插拔(SFP)
  • Cisco交换机

问题描述

  • EMS 日志报告光纤通道目标适配器上的链路轮盖事件:

Thu May 25 01:23:26 AEST [Netapp: fct_tpd_work_thread_0: scsitarget.ispfct.linkBreak:error]: Link break detected on Fibre Channel target adapter 0e. Firmware status code status1 0x2, status2 0x7, and status4 0x0.
Thu May 25 01:30:08 AEST [Netapp: fct_tpd_work_thread_0: scsitarget.hwpfct.linkUp:notice]: Link up on Fibre Channel target adapter 0e.

  • FC目标端口状态在下显示为联机 sysconfig -a

slot 0: Fibre Channel Target Host Adapter 0e
               (QLogic 8324 (8362) rev. 2, <ONLINE>)
               Firmware rev:      8.7.0
               Flash rev:         7.0.3
               Host Port Addr:    ae0700
               FC Nodename:       50:0a:09:80:80:84:xy:xx (500axxxxxxxxxxxx)
               FC Portname:       50:0a:09:81:80:84:yx:yy (500axxxxxxxxxxxx)
               Connection:        PTP, Fabric
               Switch Port:       sw:1/8
              SFP Vendor Name:  AVAGO
              SFP Vendor P/N:   AFBR-57F5MZ-NA3
              SFP Vendor Rev:   01
              SFP Serial No.:   AC1804Jxxxx
              SFP Connector:    LC
              SFP Capabilities: 4, 8, 16 Gbit/S

  • FC目标端口显示 link disconnected 在下 sysconfig -a 

slot 0: Fibre Channel Target Host Adapter 0d
         (QLogic 8324 (8362) rev. 2, <LINK DISCONNECTED>)
         Firmware rev:    8.9.0
         Flash rev:      7.0.3
         Host Port Addr:   000000
         FC Nodename:     50:0a:09:80:80:84:xy:xx (500axxxxxxxxxxxx)
         FC Portname:     50:0a:09:80:80:84:xy:xx (500axxxxxxxxxxxx)
         Connection:     No link
         Switch Port:     Unknown
       SFP Vendor Name:   FINISAR CORP.
       SFP Vendor P/N:   FTLF8529P4BCVAN1
       SFP Vendor Rev:   A
       SFP Serial No.:   P17BX7G
       SFP Connector:    LC
       SFP Capabilities:  4, 8, 16 Gbit/Sec

  • 根据 fcp-adapter.xml 日志、Rx和Tx功率处于最佳范围。
  • 在连接到受影响端口 的Cisco交换机上、交换机端口Tx电源显示为不适用。

[2023-05-31 17:09:33] Tx Power N/A -- 1.70 dBm -13.00 dBm -1.30 dBm -9.00 dBm
[2023-05-31 17:09:33] Rx Power -2.19 dBm 3.00 dBm -15.90 dBm 0.00 dBm -11.90 dBm

  • 根据  error disabled show int brief 日志,交换机端口处于状态,并且 ITW 在下为交换机端口生成错误 show interface counters

show int brief-

 fc1/8 is down (Error disabled - bit error rate too high)

show interface counters-

[2023-05-31 17:09:32]  System Errorcode  : 0x4042001e MAC Bit error exceeded threshold
[2023-05-31 17:09:32]  Error Type     : Warning
[2023-05-31 17:09:32]  PhyPortLayer    : Fibre Channel
[2023-05-31 17:09:32]  Port(s) Affected  : fc1/8
[2023-05-31 17:09:32]  Error Description : MAC Bit error exceeded threshold [ITW]

  •  我们可以在下看到交换机端口上的端口轻拍条目 show logging log

[2023-05-31 17:09:40]  2023 May 22 09:42:24 sw %PORT-5-IF_DOWN_ADMIN_DOWN: %$VSAN 10%$ Interface fc1/8 is down (Administratively down)  CS1A-naclu01-02_e0e
[2023-05-31 17:09:40]  2023 May 22 09:42:27 sw %PORT-5-IF_UP: %$VSAN 10%$ Interface fc1/8 is up in mode F  CS1A-naclu01-02_e0e
023 May 25 01:29:55 sw %PORT-5-IF_DOWN_ADMIN_DOWN: %$VSAN 10%$ Interface fc1/8 is down (Administratively down) xxxx
[2023-05-31 17:09:40]  2023 May 25 01:30:08 sw %PORT-5-IF_UP: %$VSAN 10%$ Interface fc1/8 is up in mode F  xxxx

  • 可以执行以下步骤进一步隔离问题描述:

  1. 重新拔插 存储和交换机端口上的电缆/SFP。

  2. 执行端到端电缆测试(包括配线板),如果电缆有故障,请更换电缆。

  3. 如果缆线没有故障、请先更换交换机端的SFP、因为Tx电源为NA。

注: 要隔离交换机端口不是问题描述电缆、可将其移至交换机端的未使用/空闲端口、并查看链路是否正常工作。

  1. 如果问题描述仍然存在,则在这种情况下将更换存储端SFP。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.