跳转到主内容

Brocade FC 端口脱机且处于 IN_Sync 状态

Views:
349
Visibility:
Public
Votes:
2
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • 所有 Brocade 硬件平台
  • 所有 Brocade 网络结构操作系统( FOS )平台

问题描述

连接到终端设备(主机,存储, ATTO 等)的 Brocade 光纤通道端口正在从正常状态切换到不具有网络结构 WWPN 登录的 "in_sync" 状态:

正常

brocade_sw:admin> switchshow
switchName:   brocade_sw
switchType:   118.1
switchState:   Online   
switchMode:   Native
switchRole:   Subordinate
switchDomain:   6
switchId:   fffc06
switchWwn:   10:xx:xx:xx:xx:xx:xx:xx
zoning:      ON (ZONING_CONFIG)
switchBeacon:   OFF
HIF Mode:   OFF

Index Port Address  Media Speed   State     Proto
==================================================
  0   0   060000   id   16G    Online    FC  F-Port  21:00:00:0e:1e:e9:bc:93 
  1   1   060100   id   16G    No_Light   FC  (POD license not assigned or reserved yet) Disabled (Persistent) 
  2   2   060200   id   16G    Online    FC  F-Port  50:0a:09:81:03:b3:67:a0 
  3   3   060300   id   16G    Online    FC  F-Port  10:00:00:90:fa:e6:c6:16 
  4   4   060400   id   16G    No_Light   FC  (POD license not assigned or reserved yet) Disabled (Persistent) 
  5   5   060500   id   16G    No_Light   FC  (POD license not assigned or reserved yet) Disabled (Persistent) 
  6   6   060600   --   16G    No_Module   FC  (POD license not assigned or reserved yet) Disabled (Persistent) 
  7   7   060700   --   16G    No_Module   FC  (POD license not assigned or reserved yet) Disabled (Persistent) 
  8   8   060800   id   16G    Online   FC  F-Port  22:00:00:10:86:a5:0a:c0 

 

已关闭:

brocade_sw:admin> switchshow
switchName:    brocade_sw
switchType:    118.1
switchState:   Online
switchMode:    Native
switchRole:    Subordinate
switchDomain:   6
switchId:     fffc06
switchWwn:    10:xx:xx:xx:xx:xx:xx:xx
zoning:      ON (ZONING_CONFIG)
switchBeacon:   OFF
HIF Mode:     OFF

Index Port Address  Media Speed   State     Proto
==================================================
  0   0   060000   id   16G    Online    FC  F-Port  21:00:00:0e:1e:e9:bc:93
  1   1   060100   id   16G    No_Light   FC  (POD license not assigned or reserved yet) Disabled (Persistent)
  2   2   060200   id   16G    Online    FC  F-Port  50:0a:09:81:03:b3:67:a0
  3   3   060300   id   16G    Online    FC  F-Port  10:00:00:90:fa:e6:c6:16
  4   4   060400   id   16G    No_Light   FC  (POD license not assigned or reserved yet) Disabled (Persistent)
  5   5   060500   id   16G    No_Light   FC  (POD license not assigned or reserved yet) Disabled (Persistent)
  6   6   060600   --   16G    No_Module   FC  (POD license not assigned or reserved yet) Disabled (Persistent)
  7   7   060700   --   16G    No_Module   FC  (POD license not assigned or reserved yet) Disabled (Persistent)
  8   8   060800   id   16G  In_Sync   FC

 

按照以下步骤隔离问题描述:

  • 如果Tx和Rx值在最佳范围内、请验证 与连接到交换机端口的终端设备的端到端连接、包括电缆、配线板和端口速度。
  • 如果在可能的硬件更换后未发现其他指示灯、请卸下、清洁并重新拔插终端设备SFP、电缆和配线板连接(如果适用)以及交换机SFP。
  • 如果一切正常、并且问题描述仍然存在、请将其移至 交换机端的下一个可用端口并验证状态。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.