BES-53248 集群交换机 NDU 无法升级到 EFOS 3.7.0.4 及更高版本
适用场景
- BES — 53248
- EFOS 3.7.0.4 或 3.8.0.2
- 集群互连交换机
问题描述
- 将一个 BES-53248 集群网络交换机从 EFOS 3.3.x.x 或 3.4.x.x 升级到 EFOS 3.7.0.4 或 3.8.0.2 后,交换机间链路( ISL )和端口通道将标记
Down
为状态。
# show port-channel all
Log. Channel Admin Mbr Device/ Port Port
Intf Name Min Link Mode Type Ports Timeout Speed Active
------- --------------- ---- ------ ------ ---- ------- ------------- --------- -------
1/1 Cluster-ISL 1 Down En. Dyn. 0/55 actor/long 100G Full False
partner/long
0/56 actor/long 100G Full False
partner/long
# show port all
Admin Physical Physical Link Link LACP Actor
Intf Type Mode Mode Status Status Trap Mode Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/1 Enable 10G Full 10G Full Up Enable Enable long
0/2 Enable 10G Full 10G Full Up Enable Enable long
0/3 Enable 10G Full 10G Full Up Enable Enable long
0/4 Enable 10G Full 10G Full Up Enable Enable long
....
0/55 PC Mbr Enable 100G Full Down Enable Enable long
0/56 PC Mbr Enable 100G Full Down Enable Enable long
- AutoSupport 会生成警报,报告交换机 ISL 已关闭,类似于:
HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW1/Slot: 0 Port: 55 100G - Level]) ALERT
HA Group Notification (Health Monitor process cshm: SwitchIfIslDownWarn_Alert[SW2/ Link Aggregate 1]) ALERT
- 如果在集群互连 ISL 关闭的情况下手动将集群 LIF 还原到主端口,则还原集群 LIF 的节点会发生中断(此节点上的 LIF 和卷不会提供数据),并且其集群应用程序会在该节点上脱机