跳转到主内容

如何确定电源的 NetApp 部件号 Brocade 交换机的电源( PS/PSU )或风扇

Views:
137
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • SAN
  • MetroCluster
  • Brocade 交换机 G620 , 6520 , 6510 , 6505 , 5100 , X6-4 和 X6-8

问题描述

Brocade 6520 、 6510 、 6505 或 5100 交换机上报告的电源或风扇出现故障:

  • 报告错误的 PS :

psshow :

Power Supply #1 is OK
Airflow Direction : Portside Exhaust (Reverse)
Power Supply #2 is faulty*
* = No system control access to power supply.

  • 报告风扇故障:

fanshow        :
Fan 1 is Ok, speed is 4071 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4119 RPM
Fan 4 is Ok, speed is 18977 RPM
Fan 5 is Unknown

  • Brocade X6-4 和 Brocade X6-8 上报告的电源或风扇出现故障:

psshow        :

Power Supply #1 is OK
V10N18,   DUCXXXXXXHJ      ,23-0000161-01,A0,DELTA,ECXXXXXXX42     ,00,DUXXXX8N
Power Supply #2 is faulty
V10N22,   DUCXXXXXX1H      ,23-0000161-01,A0,DELTA,ECXXXXXXX42     ,00,DUXXXX2N

fanshow        :
Fan 1 is Ok, speed is 4067 RPM
Fan 2 is faulty
Fan 3 is Ok, speed is 4067 RPM

Brocade X6-4 导向器:两个风扇组件(非端口端排气或进气)用于 1+1 冗余。每个组件包含 2 个风扇、总共 4 个。系统需要 4 个正常工作的风扇中的 3 个。一个风扇组件可以热插拔、但必须立即更换。

Brocade X6-8 Director :三个风扇组件、非端口端排气或进气、可实现 2+1 冗余。每个组件总共包含 2 个风扇,共 6 个。系统需要 6 个正常工作的风扇中的 5 个。一个风扇组件可以热插拔、但必须立即更换。

6505 交换机还提供了一个单热交换 PS 单元选项。如果此电源出现故障,则交换机将关闭,并且不会出现任何 LED 指示灯。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.