跳转到主内容

节点关闭、并显示monitor.shutdown.brokenDisk:EMERGENCY"错误

Views:
45
Visibility:
Public
Votes:
0
Category:
fas-systems<a>反馈</a><a>944990</a>
Specialty:
hw
Last Updated:

状态信息

适用场景

  • ONTAP 9
  • FAS / AFF型号

问题描述

monitor.shutdown.brokenDisk

如果 自动关闭序列在  每个 CallHome.shUTDON.pending过期 ( RAID组在指定的时间间隔内处于降级模式。默认值通常为24小时)、则会出现此消息。  

  • 节点关闭并显示以下错误、并且未执行接管:

示例:

[Node-01: statd: monitor.brokenDisk.notice:info]: When two disks are broken in raid_dp volume, the system shuts down automatically every 24 hours to encourage you to replace the disk. If you reboot the system it will run for another 24 hours before shutting down. (The 24 hour timeout may be increased by altering the "raid.timeout" value using the "options" command.)
[Node-01: statd: monitor.shutdown.brokenDisk:EMERGENCY]: data disk,parity disk in RAID group "/aggr0_n1/plex0/rg0" are broken. Halting system now.
[Node-01: shutdown_thread0: ha.localNodeShutDown:notice]: Shutdown of the local node has been initiated with inhibit_takeover set to TRUE.
[Node-01: shutdown_thread0: kern.shutdown:notice]: System shut down because : "BROKEN DISK".

  • 同一个RAID-DP组中的两个磁盘出现故障、并处于"双降级"状态:

示例:    

Aggregate aggr0_n1 (online, raid_dp, degraded) (block checksums)
  Plex /aggr0_n1/plex0 (online, normal, active, pool0)
   RAID group /aggr0_n1/plex0/rg0 (double degraded, block checksums)


RAID Disk      Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
---------     ------     ------------- ---- ---- ---- ----- --------------   --------------
dparity       0d.03.0    0d   3   0   SA:A   0   SAS 10000 1142352/2339537408 1144641/2344225968 
parity        FAILED            N/A             1142352/ -
data         FAILED            N/A             1142352/ -

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.