在 RMA 后, x336_TTCRE04TA07 产品 ID 更改为 X477_TTCRE04TA07

Views:
17
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • x336_TTCRE04TA07
  • ONTAP 9

问题描述

在 RMA 后, x336_TTCRE04TA07 产品 ID 更改为 X477_TTCRE04TA07
 
 
示例:
 
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
Firmware rev: 03.08.09.00
Base WWN: 5:00a098:00e72da:34
Phy State: [4] Enabled, 12.0 Gb/s
[5] Enabled, 12.0 Gb/s
[6] Enabled, 12.0 Gb/s
[7] Enabled, 12.0 Gb/s
03.0 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.1 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.2 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.3 : NETAPPX477_TTCRE04TA07NA02 3807.8GB 520B/sect (81xxxxxxxxx)
03.4 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.5 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.6 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.7 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.8 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.9 : NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.10: NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
03.11: NETAPP X336_TTCRE04TA07 NA03 3807.8GB 520B/sect (31xxxxxxxxx)
04.0 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (31xxxxxxxxx)
04.1 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (41xxxxxxxxx)
04.2 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (41xxxxxxxxx)
04.3 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (41xxxxxxxxx)
04.4 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (41xxxxxxxxx)
04.5 : NETAPP X336_TTCRE04TA07 NA04 3807.8GB 520B/sect (41xxxxxxxxx)
Shelf 0: DS212-12 Firmware rev. IOM12E A: 0220 IOM12E B: 0220
Shelf 1: DS212-12 Firmware rev. IOM12 A: 0270 IOM12 B: 0270
Shelf 2: DS212-12 Firmware rev. IOM12 A: 0270 IOM12 B: 0270
Shelf 3: DS212-12 Firmware rev. IOM12 A: 0270 IOM12 B: 0270
Shelf 4: DS212-12 Firmware rev. IOM12 A: 0270 IOM12 B: 0270

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.