适用场景

FAS2750

问题解答

  • 当位于外部磁盘架中的一个PSU首次关闭电源时、两个节点上应显示以下EMS事件:

Thu Aug 18 13:28:59 +0900 [Nodename: dsa_worker2: ses.status.psWarning:error]: DS224-12 (S/N SHFNCxxxx000xxx) shelf 1 on channel 0a power warning for Power supply 1: warning status; DC undervoltage. This module is on the rear of the shelf at the bottom left.
Thu Aug 18 13:29:26 +0900 [Nodename: dsa_worker2: ses.status.psError:alert]: DS224-12 (S/N SHFNCxxxx000xxx) shelf 1 on channel 0a power error for Power supply 1: critical status; AC Fail. This module is on the rear of the shelf at the bottom left.
Thu Aug 18 13:29:26 +0900 [Nodename: dsa_worker2: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
Thu Aug 18 13:29:35 +0900 [Nodename: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Thu Aug 18 13:29:35 +0900 [Nodename: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT

  • 如果同一PSU在6小时内关闭电源、 ses.status.psWarningses.status.psError 将被禁止:

Thu Aug 18 13:43:26 +0900 [Nodename: dsa_worker2: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
Thu Aug 18 13:43:35 +0900 [Nodename: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Thu Aug 18 13:43:35 +0900 [Nodename: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT

  • 这是外部磁盘架的预期行为、来自同一警报资源的相同警告消息会在6小时内被禁止。

追加信息

  • 可以通过确认PSU状态system node run -node * -command environment status
  • 如果位于内部磁盘架(机箱)中的PSU发生故障、则这两个EMS事件将永远不会被禁止。

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.