为什么在固件升级期间 SP/BMC 重新启动?

Views:
17
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • 所有平台
    • ASA 系统
    • AFF 系统
    • FAS 系统

解答

SP/BMC 更新完成后, SP/BMC 将自动重新启动。您无需手动触发 SP/BMC 重新启动。

  • 此行为是预期的。

Firmware update will need to reboot the SP on completion. If your console connection is through the SP, it will be disconnected.

  • 要显示 SP/BMC 更新状态,包括是否正在进行更新,更新开始和结束时间以及完成百分比:
system service-processor image update-progress show -node node1
 
 
Node: node1
Latest SP Firmware Update Start Timestamp: 7/18/2017 12:22:37
Latest SP Firmware Update Percentage Done: 100
Latest SP Firmware Update End Timestamp: 7/18/2017 12:28:14
Is Update in Progress: no
 
  • 验证 SP/BMC 是否联机并运行预期版本:

system service-processor show -node node1

其他信息

  • 有关此信息,请参见 mysupport.NetApp.com下载 >固件> 系统固件和诊断
  • 下载页面将提供更新步骤 SP/BMC

 