跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

在 AUP 中、磁盘架和节点之间的 PSU 警报有何区别

Views:
14
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS8200
  • FAS2620
  • DS212C

解答

  • DS212C 或 DS2246 等磁盘架在 PSU 发生故障时会发出以下 ASUP 警报。

示例:

(SHLEF POWER INTERRUPTED) ERROR
(SHELF_FAULT) ERROR

 

  • FAS8200 或 FAS6xxx 和 FAS3xxx 等节点在 PSU 发生故障时会发出以下 ASUP 警报。

示例:

(CHASSIS POWER SUPPLY OFF:PS1) ERROR
(CHASSIS POWER SUPPLY DEGRADED:PS1)ERROR

  • 像 FAS2xxx 这样的节点具有板载 IOM 和内部磁盘架、因此在 PSU 发生故障时会发出以下 ASUP 警报。

示例:

(SHLEF POWER INTERRUPTED) ERROR
(SHELF_FAULT) ERROR
(CHASSIS POWER DEGRADED:Power Supply Status Critical:PSU1) ERROR

 

Scan to view the article on your device