跳转到主内容
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

Storage Show Expander Output 中的端口状态是什么?

Views:
22
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用于

  • DS2246
  • DS4246

解答

storage show expander如何解读 Data ONTAP 命令行中的端口状态输出?

Data ONTAP 可以使用以下端口状态来描述 PHY 端口的状态:

  • OK (正常)— PHY 工作正常
  • 空-托架中没有驱动器或主机端口没有电缆
  • 由于出现过多的 DWORD 错误而禁用了 Dis/Invwd-PHY
  • 由于存在过多的差异错误, Dis/dIPA — PHY 已禁用
  • 由于丢失双字节同步而禁用 Dis/Loswd-PHY
  • 由于 PHY 重置问题错误过多而禁用 DI/ 重置 - PHY
  • 由于 CRC 错误过多而禁用 Dis/CRC-PHY
  • 由于 PHY 更改事件过多而禁用 Dis/PHCHG — PHY
  • 由于正在设置集群镜像位、 DIS/MIR-PHY 已禁用(检查伙伴)
  • Dis/Resv* —已禁用 PHY 以模拟 SCSI 保留空间
  • DIS/MAN-PHY 被手动禁用 (Mfg仅测试)
  • 由于扩展器参考时钟错误, DIS/CLK -PHY 被禁用。
  • DIS/UNKWN-PHY 等待扩展器固件初始化。
  • DIS/UNUSD-PHY 已禁用和未使用(保留供将来使用)
  • ???0 xxx - 无法解码端口状态 XX

 

Scan to view the article on your device