跳转到主内容

服务处理器 API 服务无响应导致命令超时并截断 AutoSupport

Views:
27
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • FAS/AFF
  • ONTAP 9
  • 底板管理控制器( BMC )
  • 服务处理器 (SP)

问题描述

  1. 平台子系统数据的 AutoSupport 收集在 120 秒后超时
cluster::*> system node autosupport manifest show -status *-limit -fields subsys,status,error,time-collected  -subsys !log_files -time-collected >120000
node           seq-num prio-num subsys   time-collected status error
-------------- ------- -------- -------- -------------- ------------------------------- -----
node-01       812     49      platform 125315         collection-truncated-time-limit
node-01       804     133      platform 125300        collection-truncated-time-limit
node-01       797     49       platform 125197         collection-truncated-time-limit
  1. system node power showsystem node environment sensors show 命令等 120 秒后超时:

cluster::*> system node environment sensors show -node node-01

Warning: Unable to list entries on node node-01. The Service Processor on node "node-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.

Warning: Unable to list entries on node node-01. Timeout: Operation "environment_sensors_iterator::next_imp()" took longer than 50 seconds to complete [from mgwd on node "node-01" (VSID: -1) to mgwd at 169.XXX.XX.XXX]

Error: show failed: Timeout: Operation "environment_sensors_iterator::next()" took longer than 50 seconds to complete [from mgwd on node "node-01" (VSID: -1) to mgwd at 169.XXX.XX.XXX]

cluster::> system node power show -node node-01

Error: The Service Processor on node "node-01" is not reachable. Verify
    that the SP or BMC is online, verify that api-service is enabled on the
    SP or BMC, verify that the partner node is running, check if pings from
    SP or BMC to partner node work, check if hw-assist keep-alives are
    normal, check that network ports are configured correctly and are
    functional (up). Then, try the command again.

 
Warning: Unable to list entries on node node-01. SP API service is not available on node "node-01". 
    Check SP firmware version and Data Ontap(R) version.

Error: show failed: SP API service is not available on node
    "node-01". Check SP firmware version and Data Ontap(R) version.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.