适用场景

  • ONTAP 9
  • FAS8300

问题描述

system health alert show 报告 AllPathToOneEndOfStack_Alert

示例:

Monitor   node-connect
Alert ID   AllPathToOneEndOfStack_Alert
Alerting Resource   1
Subsystem   SAS-connect
Indication Time   Wed Nov 17 13:29:18 2021
Perceived Severity   Major
AutoSupport Triggered   true
Probable Cause   Cable_tamper
Corrective Actions   
1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Connect controller CNSENAS07-01 to the first and last disk shelves of stack 1.
3. Verify that controller CNSENAS07-01 is cabled to IOM A and IOM B of stack 1.
4. Contact technical support if the alert persists.
Node ID    Node1
Enable Asup for This Alert   true
Alert Clear Time

 