In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

系统首次启动时, SP 报告 "RTC power failure error"

Views:
13
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • 服务处理器 (SP)
  • 实时时钟( RTC )

问题描述

  • 系统RTC power failure error首次启动时, SP 会报告 " " 。

Record 48: Thu Jan 01 00:00:01.000000 2015 [SysFW.warning]: RTC power failure error.

P3.3V                    normal          3307 mV     2957 mV     3027 mV     3570 mV     3657 mV
P3.3V Batt              critlow         1400 mV     2537 mV     2695 mV     3307 mV     3447 mV
P3.3V Standby            normal          3290 mV     2957 mV     3027 mV     3570 mV     3657 mV

  • RTC 电池将在短时间内正常运行。

Record 60: Thu Jan 01 00:00:23.000000 2015 [Boot Loader.notice]: Received time sync
Record 61: Thu Jan 01 00:00:40.050000 2015 [BMC.notice]: Successfully woke up the battery

P3.3V                    normal          3307 mV     2957mV     3027mV      3570mV     3657mV
P3.3V Batt               normal          2817 mV     2537mV     2695mV      3307mV     3447mV

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support