跳转到主内容

SP或BMC报告严重:检测信号已停止

Views:
40
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • FAS 27xx
  • FAS 26XX
  • AFF A220
  • FAS 8200
  • 服务处理器 (SP)
  • 底板管理控制器( BMC )

问题描述

  • 节点崩溃。
  • events all 报告 Heartbeat stopped检测信号已停止

Record 1731: Wed May 06 22:18:16.800000 2020 [BMC.critical]: Heartbeat stopped
Record 1732: Wed May 06 22:18:16.830000 2020 [Trap Event.warning]: hwassist loss_of_heartbeat (30)
Record 1733: Wed May 06 22:19:05.460000 2020 [ASUP.notice]: First notification email | (HEARTBEAT_LOSS) WARNING | Send failed
Record 1734: Wed May 06 22:33:22.320000 2020 [ASUP.notice]: Reminder email | (HEARTBEAT_LOSS) WARNING | Sent

Record 1679: Thu May 12 01:04:07 2022 [SP.critical]: Heartbeat stopped
Record 1680: Thu May 12 01:07:19 2022 [ASUP.notice]: Reminder email | (REBOOT (abnormal)) WARNING | Sent

  • events all 5月报告 SP load is high

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device