升级ONTAP 后SP固件自动更新失败
适用场景
- FAS2750
- BMC 11.7 > 11.8
- ONTAP 升级9.8P11 > 9.11.1P2
问题描述
- ONTAP 升级后、SP固件无法更新
[Node-01: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
system health subsystem show
将服务处理器列为已降级
::> system health subsystem show
Subsystem
Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor degraded
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.
- SP mlog
[kern_servprocd:info:5478] 0x80acc8000: 0: NOTICE: Servprocd::SpUpdate: SpUpdateStateHandleEvent: SP update from version 11.7 to version 11.8 has been scheduled.
[kern_servprocd:info:5478] 0x80acc8000: 0: NOTICE: Servprocd::SpUpdate: UpdateSmfState: processing ck_auto_update_scheduled.
[kern_servprocd:info:5478] 0x80c3af200: 0: NOTICE: Servprocd::SpUpdate: prepareImage: SP firmware image files were successfully checked for compression.
[kern_servprocd:info:5478] 0x80c3af200: 0: NOTICE: Servprocd::SpUpdate: prepareImage: Creating /mroot/etc/RLM_FW/sp_image.tar.gz image for network transfer.
[kern_servprocd:info:5478] 0x80c3af200: 0: NOTICE: Servprocd::SpUpdate: prepareImage: /mroot/etc/RLM_FW/sp_image.tar.gz image has been successfully created for network transfer to SP.
[kern_servprocd:info:5478] 0x80c3af200: 0: NOTICE: Servprocd::SpUpdate: update: SP firmware image for network transfer has been created.
[kern_servprocd:info:5478] 0x80c3af200: 0: NOTICE: Servprocd::SpUpdate: transferImage: sending /mroot/etc/RLM_FW/sp_image.tar.gz to SP, destination: /mnt/sapps/sp_image.tar.gz.
[kern_servprocd:info:5478] 0x29077a: SpUpdateOp::startUpdate()+8474
[kern_servprocd:info:5478] 0x291e6b: SpUpdateOp::startUpdate()+14347
[kern_servprocd:info:5478] 0x28e9ea: SpUpdateOp::startUpdate()+906
[kern_servprocd:info:5478] 0x80c3af200: 0: NOTICE: Servprocd::SpUpdate: update: SP firmware image has been successfully transferred to SP using network interface.
[kern_servprocd:info:5478] 0x80c3af200: 0: NOTICE: Servprocd::SpUpdate: writeImage: sending spcs update command to write SP firmware image to flash.
[kern_servprocd:info:5478] 0x80c3af200: 0: ERR: Servprocd::CLI: sp_update_worker : TTX ERROR: 7
[kern_servprocd:info:5478] 0x80c3af200: 0: ERR: Servprocd::CLI: sp_update_worker : sp reset connection, marking update success, we will catch failures in post update stage.
[kern_servprocd:info:5478] 0x80c3af200: 0: ERR: Servprocd::CLI: sp_update_worker : EXCEPTION Occured in closing the spcc transport
[kern_servprocd:info:5478] 0x80c3af200: 0: ERR: Servprocd::SpUpdate: writeImage: spcs sp update command failed (The Service Processor on node "Node-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.)