跳转到主内容

断电后使聚合脱机

Views:
1
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009210516</a>
Specialty:
hw
Last Updated:

适用场景

  • 所有FAS 和AFF 系统
  • 所有 ONTAP 版本
  • FlashPool
  • 磁盘驱动器X446_PHM2200MCTO
    • 固件NA04
  • 断电

问题描述

  • 断电后、一个聚合脱机、无法联机

cluster::> storage aggregate modify -aggregate hybrid_aggregate -state online
 

Error: command failed: Failed to bring aggregate "hybrid_aggregate" online. Reason: Aggregate 'hybrid_aggregate' has failed and cannot be brought online.

  • 聚合的SSD RAID组缺失

Aggregate hybrid_aggregate (failed, mixed_raid_type, partial, hybrid_enabled) (block checksums)
  Plex /hybrid_aggregate/plex0 (offline, failed, inactive)
   RAID group /hybrid_aggregate/plex0/rg0 (normal, block checksums, raid_dp)

    RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
    ---------   ------     ------------- ---- ---- ---- ----- --------------   --------------
    dparity    2b.11.4    2b   11  4   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768 
    parity     0b.11.5    0b   11  5   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768 
    data      2b.11.6    2b   11  6   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768 
    data      0b.11.7    0b   11  7   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768 
  Plex is missing 1 RAID group.

  • 磁盘X446_PHM2200MCTO显示 Failed-Unsupported 在中 SYSCONFIG-A

11.0 : NETAPP   X446_PHM2200MCTO NA04   0.0GB 0B/sect (Failed-Unsupported)
11.1 : NETAPP   X446_PHM2200MCTO NA04   0.0GB 0B/sect (Failed-Unsupported)
11.2 : NETAPP   X446_PHM2200MCTO NA04   0.0GB 0B/sect (Failed-Unsupported)
11.3 : NETAPP   X446_PHM2200MCTO NA04   0.0GB 0B/sect (Failed-Unsupported)

  • 在发生故障之前、磁盘X446_PHM2200MCTO已打开电源超过70000小时(~8年)